--/**               AKCP, Inc                                                */
--/**               Proprietary and Confidential Information                 */
--/**                                                                        */
--/** This material contains, and is part of a computer software program     */
--/** which is, proprietary and confidential information owned by AKCP, INC. */ 
--/** The program, including this material,                                  */
--/** may not be duplicated, disclosed or reproduced in whole or in part for */
--/** any purpose without the express written authorization of AKCP, Inc     */
--/** All authorized reproductions must be marked with this legend.          */
--/**                                                                        */
--/**                                                                        */
--/**                         Copyright (c) 1995-01                          */
--/**                         AKCP, Incorporated                             */
--/**                         All rights reserved                            */
--/**                                                                        */
--/***************************************************************************/


HHMSAGENT-MIB DEFINITIONS ::= BEGIN

IMPORTS
        enterprises, IpAddress
                FROM RFC1155-SMI
        OBJECT-TYPE
                FROM RFC-1212
        DisplayString
                FROM RFC1213-MIB
        TRAP-TYPE
                FROM RFC-1215;


   akcp	OBJECT IDENTIFIER ::= { enterprises 3854 }
   hhmsagent	OBJECT IDENTIFIER ::= { akcp 1 }


      hhmsAgentSummary         OBJECT IDENTIFIER  ::=  {  hhmsagent 1   }

         hhmsAgentLocation OBJECT-TYPE
            SYNTAX  DisplayString
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
            "The Agent location"
            ::=  {  hhmsAgentSummary 1   }

         hhmsAgentStatus OBJECT-TYPE
            SYNTAX  INTEGER {
            noStatus(1),
            normal(2),
            warning(3),
            critical(4),
			   sensorError(5)
				}
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
            "The current status of this Agent. The status of the agent is the worst status of all the sensors usder the control of this agent."
            ::=  {  hhmsAgentSummary 2   }

         hhmsNumberBadSensors OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
            "How many sensors controlled by this agent are not functioning properly"
            ::=  {  hhmsAgentSummary 4   }

         hhmsLocationBadSensor OBJECT-TYPE
            SYNTAX  DisplayString
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
            "The Location of the first bad sensor controlled by this agent."
            ::=  {  hhmsAgentSummary 5   }

         hhmsAgentManufName OBJECT-TYPE
            SYNTAX  DisplayString
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
            "The manufacturers name"
            ::=  {  hhmsAgentSummary 6   }

         hhmsAgentHelpUrl OBJECT-TYPE
            SYNTAX  DisplayString
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
            "The URL of the web based help"
            ::=  {  hhmsAgentSummary 7   }

         hhmsAgentHtmlView OBJECT-TYPE
            SYNTAX  INTEGER {
            sensorArray(1),
            sensorArrayPro(2),
            advanced(3)
				}
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
            "Which view of the sensors the user is served via the web server"
            ::=  {  hhmsAgentSummary 8   }

         hhmsAgentHtmlStandardTitle OBJECT-TYPE
            SYNTAX  DisplayString
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
            "The titles of the standard html view"
            ::=  {  hhmsAgentSummary 9   }

         hhmsAgentHtmlStandardButton OBJECT-TYPE
            SYNTAX  DisplayString
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
            "The buttons of the standard html view"
            ::=  {  hhmsAgentSummary 10   }


      hhmsSensor OBJECT IDENTIFIER  ::=  {  hhmsagent 2 }

         hhmsSensorArrayTable OBJECT IDENTIFIER ::= { hhmsSensor 2  }
 
            hhmsSensorArrayEntry OBJECT IDENTIFIER ::= { hhmsSensorArrayTable 1  }

               hhmsSensorArrayHost OBJECT-TYPE
                  SYNTAX  IpAddress
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The Host of this sensor, this is the IP address"
                  ::=  {  hhmsSensorArrayEntry 1   }

               hhmsSensorArrayUseDHCP OBJECT-TYPE
                  SYNTAX  INTEGER {
			         yes(1),
			         no(2)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "To use DHCP enter a 1, to use a static IP address enter a 2"
                  ::=  {  hhmsSensorArrayEntry 2   }


               hhmsSensorArrayMAC OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The MAC address of this sensor."
                  ::=  {  hhmsSensorArrayEntry 3   }

               hhmsSensorArraySetCommunity OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The sensorArray community string used for snmp Sets"
                  ::=  {  hhmsSensorArrayEntry 4   }

               hhmsSensorArrayGetCommunity OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The sensorArray community string used for snmp Gets"
                  ::=  {  hhmsSensorArrayEntry 5   }

               hhmsSensorArrayDescription OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "A Description of this sensorArray"
                  ::=  {  hhmsSensorArrayEntry 6   }

               hhmsSensorArrayLocation OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The description of the physical location of this sensorArray"
                  ::=  {  hhmsSensorArrayEntry 7   }

               hhmsSensorArrayLastUpdate OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The last time the sensorArray was read"
                  ::=  {  hhmsSensorArrayEntry 8  }

               hhmsSensorArrayStatus OBJECT-TYPE
                  SYNTAX  INTEGER {
		   	      noStatus(1),
			         normal(2),
		   	      sensorError(7)
                  }
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The current status of this sensorArray"
                  ::=  {  hhmsSensorArrayEntry 9   }
   
               hhmsSensorArrayOnline OBJECT-TYPE
                  SYNTAX  INTEGER {
			         online(1),
			         offline(2)
                  }
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "If this sensorArray is currently online"
                  ::=  {  hhmsSensorArrayEntry 10   }
   
               hhmsSensorArrayGoOnline OBJECT-TYPE
                  SYNTAX  INTEGER {
			         goOnline(1),
			         goOffline(2)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "To put online enter a 1, to take offline enter a 2"
                  ::=  {  hhmsSensorArrayEntry 11   }

               hhmsSensorArrayReadInterval OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "How many seconds between readings of this sensor"
                  ::=  {  hhmsSensorArrayEntry 12  }

               hhmsSensorArrayReceiveTimeout OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "How many seconds to wait to receive data from the sensor"
                  ::=  {  hhmsSensorArrayEntry 13  }
   
               hhmsSensorArrayReceiveRetries OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "How many times to retry to receive data before giving up. A -1 means never give up trying"
                  ::=  {  hhmsSensorArrayEntry 14   }

               hhmsSensorArrayVersion OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The version of this SensorArray"
                  ::=  {  hhmsSensorArrayEntry 15   }

               hhmsSensorArrayTempTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArrayTempEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor."
                  ::=  {  hhmsSensorArrayEntry 16   }

               hhmsSensorArrayTempEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArrayTempEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArrayTempEntry Table"
                  INDEX         { hhmsSensorArrayTempIndex }
                  ::=  {  hhmsSensorArrayTempTable 1 }

                  HhmsSensorArrayTempEntry ::= SEQUENCE {
                     hhmsSensorArrayTempDescription
                        DisplayString,
                     hhmsSensorArrayTempLocation
                        DisplayString,
                     hhmsSensorArrayTempDegree
                        INTEGER,
                     hhmsSensorArrayTempStatus
                        INTEGER,
                     hhmsSensorArrayTempOnline
                        INTEGER,
                     hhmsSensorArrayTempGoOnline
                        INTEGER,
                     hhmsSensorArrayTempHighWarning
                        INTEGER,
                     hhmsSensorArrayTempHighCritical
                        INTEGER,
                     hhmsSensorArrayTempLowWarning
                        INTEGER,
                     hhmsSensorArrayTempLowCritical
                        INTEGER,
                     hhmsSensorArrayTempRearm
                        INTEGER,
                     hhmsSensorArrayTempDegreeType
                        INTEGER,
                     hhmsSensorArrayTempSensorType
                        INTEGER,
                     hhmsSensorArrayTempTestStatus
                        INTEGER,
                     hhmsSensorArrayTempTestDegree
                        INTEGER,
                     hhmsSensorArrayTempIndex
                        INTEGER
                  }
                  hhmsSensorArrayTempDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this sensor"
                     ::=  {  hhmsSensorArrayTempEntry 1   }

                  hhmsSensorArrayTempLocation OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The physical location of this sensor"
                     ::=  {  hhmsSensorArrayTempEntry 2   }

                  hhmsSensorArrayTempDegree OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The degrees in this sensor"
                     ::=  {  hhmsSensorArrayTempEntry 3   }

                  hhmsSensorArrayTempStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
                     noStatus(1),
			            normal(2),
			            highWarning(3),
			            highCritical(4),
                     lowWarning(5),
                     lowCritical(6),
                     sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Sensor"
                     ::=  {  hhmsSensorArrayTempEntry 4   }
      
                  hhmsSensorArrayTempOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
			            online(1),
			            offline(2)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "If this Sensor is currently online"
                     ::=  {  hhmsSensorArrayTempEntry 5   }
   
                  hhmsSensorArrayTempGoOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         goOnline(1),
			            goOffline(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To put online enter a 1, to take offline enter a 2"
                     ::=  {  hhmsSensorArrayTempEntry 6   }
         
                  hhmsSensorArrayTempHighWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How hot this sensor gets before it sends a warning"
                     ::=  {  hhmsSensorArrayTempEntry 7   }
      
                  hhmsSensorArrayTempHighCritical OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How hot this sensor gets before it sends a critical event"
                     ::=  {  hhmsSensorArrayTempEntry 8   }
   
                  hhmsSensorArrayTempLowWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How cold this sensor gets before it sends a warning"
                     ::=  {  hhmsSensorArrayTempEntry 9   }
   
                  hhmsSensorArrayTempLowCritical OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How cold this sensor gets before it sends a critical event"
                     ::=  {  hhmsSensorArrayTempEntry 10   }
      
                  hhmsSensorArrayTempRearm OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down hhmsTempRearm degrees below warning before the status goes to normal"
                     ::=  {  hhmsSensorArrayTempEntry 11   }
   
                  hhmsSensorArrayTempDegreeType OBJECT-TYPE
                     SYNTAX  INTEGER {
   		   	      fahr(0),
	   		         celsius(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The degrees are in fahrenheit(0) or in celsius(1)"
                     ::=  {  hhmsSensorArrayTempEntry 12   }
      
                  hhmsSensorArrayTempSensorType OBJECT-TYPE
                     SYNTAX  INTEGER {
   		   	      type1(0),
	   		         type2(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The type of temperture sensor"
                     ::=  {  hhmsSensorArrayTempEntry 13   }
      
                  hhmsSensorArrayTempTestStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
			            testNoStatus(1),
			            testNormal(2),
			            testHighWarning(3),
      			      testHighCritical(4),
	      		      testLowWarning(5),
		      	      testLowCritical(6),
			            sensorError(7)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Set the status for test purposes"
                     ::=  {  hhmsSensorArrayTempEntry 14   }
   
                  hhmsSensorArrayTempTestDegree OBJECT-TYPE
                     SYNTAX  INTEGER 
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Enter the degrees in this sensor for test purposes"
                     ::=  {  hhmsSensorArrayTempEntry 15   }

                  hhmsSensorArrayTempIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..3)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the temperature sensor table"
                     ::=  {  hhmsSensorArrayTempEntry 16   }



               hhmsSensorArrayHumidityTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArrayHumidityEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the data for every Humidity Sensor in the SensorArray. Each row in the table contains data for a different Humidity Sensor."
                  ::=  {  hhmsSensorArrayEntry 17   }

               hhmsSensorArrayHumidityEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArrayHumidityEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArrayHumidityEntry Table"
                  INDEX         { hhmsSensorArrayHumidityIndex }
                  ::=  { hhmsSensorArrayHumidityTable 1 }

                  HhmsSensorArrayHumidityEntry ::= SEQUENCE {
                     hhmsSensorArrayHumidityDescription
                        DisplayString,
                     hhmsSensorArrayHumidityLocation
                        DisplayString,
                     hhmsSensorArrayHumidityPercent
                        INTEGER,
                     hhmsSensorArrayHumidityStatus
                        INTEGER,
                     hhmsSensorArrayHumidityOnline
                        INTEGER,
                     hhmsSensorArrayHumidityGoOnline
                        INTEGER,
                     hhmsSensorArrayHumidityHighWarning
                        INTEGER,
                     hhmsSensorArrayHumidityHighCritical
                        INTEGER,
                     hhmsSensorArrayHumidityLowWarning
                        INTEGER,
                     hhmsSensorArrayHumidityLowCritical
                        INTEGER,
                     hhmsSensorArrayHumidityRearm
                        INTEGER,
                     hhmsSensorArrayHumidityTestStatus
                        INTEGER,
                     hhmsSensorArrayHumidityTestPercent
                        INTEGER,
                     hhmsSensorArrayHumidityIndex
                        INTEGER
                  }
                  hhmsSensorArrayHumidityDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this sensor"
                     ::=  {  hhmsSensorArrayHumidityEntry 1   }

                  hhmsSensorArrayHumidityLocation OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The physical location of this sensor"
                     ::=  {  hhmsSensorArrayHumidityEntry 2   }

                  hhmsSensorArrayHumidityPercent OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The relative humidity percentage measured by this sensor"
                     ::=  {  hhmsSensorArrayHumidityEntry 3   }

                  hhmsSensorArrayHumidityStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
                     noStatus(1),
			            normal(2),
			            highWarning(3),
			            highCritical(4),
                     lowWarning(5),
                     lowCritical(6),
                     sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Sensor"
                     ::=  {  hhmsSensorArrayHumidityEntry 4   }
      
                  hhmsSensorArrayHumidityOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
			            online(1),
			            offline(2)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "If this Sensor is currently online"
                        ::=  {  hhmsSensorArrayHumidityEntry 5   }
   
                  hhmsSensorArrayHumidityGoOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         goOnline(1),
			            goOffline(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To put online enter a 1, to take offline enter a 2"
                     ::=  {  hhmsSensorArrayHumidityEntry 6   }
      
                  hhmsSensorArrayHumidityHighWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How high the relative humidity this sensor measures before it sends a warning"
                     ::=  {  hhmsSensorArrayHumidityEntry 7   }
      
                  hhmsSensorArrayHumidityHighCritical OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How high the relative humidity this sensor measures before it becomes critical"
                     ::=  {  hhmsSensorArrayHumidityEntry 8   }
   
                  hhmsSensorArrayHumidityLowWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How low the relative humidity this sensor measures before it sends a warning"
                     ::=  {  hhmsSensorArrayHumidityEntry 9   }
   
                  hhmsSensorArrayHumidityLowCritical OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How low the relative humidity this sensor measures before it becomes critical"
                     ::=  {  hhmsSensorArrayHumidityEntry 10   }
         
                  hhmsSensorArrayHumidityRearm OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The percent relative humidity to rearm the status. For example if status goes from normal to warning, the humidity must go down hhmsHumidityRearm below warning before the status goes to normal"
                     ::=  {  hhmsSensorArrayHumidityEntry 11   }
      
                  hhmsSensorArrayHumidityTestStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
			            testNoStatus(1),
			            testNormal(2),
			            testHighWarning(3),
      			      testHighCritical(4),
	      		      testLowWarning(5),
		      	      testLowCritical(6),
			            sensorError(7)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Set the status for test purposes"
                     ::=  {  hhmsSensorArrayHumidityEntry 12   }
   
                  hhmsSensorArrayHumidityTestPercent OBJECT-TYPE
                     SYNTAX  INTEGER 
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Enter the percent of relative humidity in this sensor for test purposes"
                     ::=  {  hhmsSensorArrayHumidityEntry 13   }

                  hhmsSensorArrayHumidityIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..2)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the Humidity sensor table"
                     ::=  {  hhmsSensorArrayHumidityEntry 14   }


               hhmsSensorArraySwitchTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArraySwitchEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
                  ::=  {  hhmsSensorArrayEntry 18   }

               hhmsSensorArraySwitchEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArraySwitchEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArraySwitchEntry Table"
                  INDEX         { hhmsSensorArraySwitchIndex }
                  ::=  { hhmsSensorArraySwitchTable 1 }

                  HhmsSensorArraySwitchEntry ::= SEQUENCE {
                     hhmsSensorArraySwitchDescription
                        DisplayString,
                     hhmsSensorArraySwitchLocation
                        DisplayString,
                     hhmsSensorArraySwitchStatus
                        INTEGER,
                     hhmsSensorArraySwitchOnline
                        INTEGER,
                     hhmsSensorArraySwitchGoOnline
                        INTEGER,
                     hhmsSensorArraySwitchDirection
                        INTEGER,
                     hhmsSensorArraySwitchNormalState
                        INTEGER,
                     hhmsSensorArraySwitchOutputLevel
                        INTEGER,
                     hhmsSensorArraySwitchTestState
                        INTEGER,
                     hhmsSensorArraySwitchIndex
                        INTEGER
                  }
                  hhmsSensorArraySwitchDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this sensor Switch"
                     ::=  {  hhmsSensorArraySwitchEntry 1   }

                  hhmsSensorArraySwitchLocation OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The physical location of this sensor Switch"
                     ::=  {  hhmsSensorArraySwitchEntry 2   }

                  hhmsSensorArraySwitchStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
		      	      noStatus(1),
			            normal(2),
			            critical(4),
	   	   	      sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Sensor, only input switches have a status"
                     ::=  {  hhmsSensorArraySwitchEntry 3  }

                  hhmsSensorArraySwitchOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
			            online(1),
			            offline(2)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "If this Sensor is currently online"
                        ::=  {  hhmsSensorArraySwitchEntry 4  }
   
                  hhmsSensorArraySwitchGoOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         goOnline(1),
			            goOffline(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To put online enter a 1, to take offline enter a 2"
                     ::=  {  hhmsSensorArraySwitchEntry 5  }

                  hhmsSensorArraySwitchDirection OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         input(0),
			            output(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To set a switch to input enter 0. To set a switch to output enter 1"
                     ::=  {  hhmsSensorArraySwitchEntry 6  }

                  hhmsSensorArraySwitchNormalState OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         closed(0),
			            open(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts."
                     ::=  {  hhmsSensorArraySwitchEntry 7  }
                     
                  hhmsSensorArraySwitchOutputLevel OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         low(0),
			            high(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "An output swith can be set to this level"
                     ::=  {  hhmsSensorArraySwitchEntry 8  }
                     
                  hhmsSensorArraySwitchTestState OBJECT-TYPE
                     SYNTAX  INTEGER {
		      	      noStatus(1),
			            normal(2),
			            critical(4),
	   	   	      sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "Enter the status of this Sensor for test purposes"
                     ::=  {  hhmsSensorArraySwitchEntry 9  }
                     
                  hhmsSensorArraySwitchIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..24)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the Switch sensor table"
                     ::=  {  hhmsSensorArraySwitchEntry 10   }


               hhmsSensorArraySerialTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArraySerialEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the data for every Serial Port in the SensorArray. Each row in the table contains data for a different Serial Port."
                  ::=  {  hhmsSensorArrayEntry 19   }

               hhmsSensorArraySerialEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArraySerialEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArraySerialEntry Table"
                  INDEX         { hhmsSensorArraySerialIndex }
                  ::=  { hhmsSensorArraySerialTable 1 }

                  HhmsSensorArraySerialEntry ::= SEQUENCE {
                     hhmsSensorArraySerialDescription
                        DisplayString,
                     hhmsSensorArraySerialLocation
                        DisplayString,
                     hhmsSensorArraySerialStatus
                        INTEGER,
                     hhmsSensorArraySerialOnline
                        INTEGER,
                     hhmsSensorArraySerialGoOnline
                        INTEGER,
                     hhmsSensorArraySerialData
                        DisplayString,
                     hhmsSensorArraySerialBaud
                        INTEGER,
                     hhmsSensorArraySerialDataBits
                        INTEGER,
                     hhmsSensorArraySerialParity
                        INTEGER,
                     hhmsSensorArraySerialStop
                        INTEGER,
                     hhmsSensorArraySerialCTS
                        INTEGER,
                     hhmsSensorArraySerialRTS
                        INTEGER,
                     hhmsSensorArraySerialConfig
                        DisplayString,
                     hhmsSensorArraySerialIndex
                        INTEGER
                  }
                  hhmsSensorArraySerialDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this Serial Port"
                     ::=  {  hhmsSensorArraySerialEntry 1   }

                  hhmsSensorArraySerialLocation OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The physical location of this Serial Port"
                     ::=  {  hhmsSensorArraySerialEntry 2   }

                  hhmsSensorArraySerialStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
		      	      noStatus(1),
			            normal(2),
			            critical(4),
	   	   	      sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Serial Port"
                     ::=  {  hhmsSensorArraySerialEntry 3  }

                  hhmsSensorArraySerialOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
			            online(1),
			            offline(2)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "If this Serial Port is currently online"
                        ::=  {  hhmsSensorArraySerialEntry 4  }
   
                  hhmsSensorArraySerialGoOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         goOnline(1),
			            goOffline(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To put online enter a 1, to take offline enter a 2"
                     ::=  {  hhmsSensorArraySerialEntry 5  }

                  hhmsSensorArraySerialData OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Write sends data, read gets data from this Serial Port"
                     ::=  {  hhmsSensorArraySerialEntry 6   }

                  hhmsSensorArraySerialBaud OBJECT-TYPE
                     SYNTAX  INTEGER {
			            baud1200(255),
			            baud2400(129),
			            baud4800(64),
			            baud9600(32),
			            baud19200(15),
			            baud28800(10),
			            baud38400(7),
			            baud57600(4),
			            baud115200(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Choose the baud rate for this serial port"
                     ::=  {  hhmsSensorArraySerialEntry 7  }

                  hhmsSensorArraySerialDataBits OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         eight(8)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Parity bit for this serial port"
                     ::=  {  hhmsSensorArraySerialEntry 8  }

                  hhmsSensorArraySerialParity OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         none(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Parity bit for this serial port"
                     ::=  {  hhmsSensorArraySerialEntry 9  }

                  hhmsSensorArraySerialStop OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         one(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Stop bits for this serial port"
                     ::=  {  hhmsSensorArraySerialEntry 10  }

                  hhmsSensorArraySerialCTS OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         on(1),
                     off(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Turn CTS on or off for this serial port"
                     ::=  {  hhmsSensorArraySerialEntry 11  }

                  hhmsSensorArraySerialRTS OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         on(1),
                     off(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "Turn RTS on or off for this serial port"
                     ::=  {  hhmsSensorArraySerialEntry 12  }

                  hhmsSensorArraySerialConfig OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this Serial Port"
                     ::=  {  hhmsSensorArraySerialEntry 13  }

                  hhmsSensorArraySerialIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..1)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the Serial table"
                     ::=  {  hhmsSensorArraySerialEntry 14   }

               hhmsSensorArrayDebug OBJECT-TYPE
                  SYNTAX  INTEGER {
      	         on(1),
                  off(0)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "Turn on or off debug messages"
                  ::=  {  hhmsSensorArrayEntry 20  }

               hhmsSensorArrayDebugIP OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The IP address to send debug messages to"
                  ::=  {  hhmsSensorArrayEntry 21  }

               hhmsSensorArrayTrapResend OBJECT-TYPE
                  SYNTAX  INTEGER {
      	         on(1),
                  off(0)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "If traps for Warning or Error should be resent. Traps for Normal status are sent once"
                  ::=  {  hhmsSensorArrayEntry 22  }

               hhmsSensorArrayTrapResendInterval OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "How often to resend mail or Traps. Enter the number of seconds from 15 to 65535. Mail for WARNING and ERROR are resent at this interval. Traps for Normal status are sent once"
                  ::=  {  hhmsSensorArrayEntry 23  }

               hhmsSensorArraySendTraps OBJECT-TYPE
                  SYNTAX  INTEGER {
                  on(1),
                  off(2)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "Turn on or off the sending of traps"
                  ::=  {  hhmsSensorArrayEntry 24  }

               hhmsSensorArrayTrapDestination OBJECT-TYPE
                  SYNTAX  IpAddress
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The IP address of the trap destination"
                  ::=  {  hhmsSensorArrayEntry 25  }

               hhmsSensorArrayTrapCommunity OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The community string of the trap destination"
                  ::=  {  hhmsSensorArrayEntry 26  }

               hhmsSensorArrayTrapDefaultGateway OBJECT-TYPE
                  SYNTAX  IpAddress
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "If the trap destination is on another network, enter the IP address of the router"
                  ::=  {  hhmsSensorArrayEntry 27  }

               hhmsSensorArrayTrapUseDefaultGateway OBJECT-TYPE
                  SYNTAX  INTEGER {
      	         on(1),
                  off(2)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "If the trap destination uses the default gateway"
                  ::=  {  hhmsSensorArrayEntry 28  }

               hhmsSensorArrayTrapDestinationMac OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "If the trap destination MAC address"
                  ::=  {  hhmsSensorArrayEntry 29  }


               hhmsSensorArraySendMail OBJECT-TYPE
                  SYNTAX  INTEGER {
                  on(1),
                  off(2)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "Turn on or off the sending of Mail"
                  ::=  {  hhmsSensorArrayEntry 30  }

               hhmsSensorArrayMailRecpt OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The email address of the Recipient"
                  ::=  {  hhmsSensorArrayEntry 31  }

               hhmsSensorArrayMailFrom OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The email address of the Sender"
                  ::=  {  hhmsSensorArrayEntry 32  }

               hhmsSensorArrayMailSmpt OBJECT-TYPE
                  SYNTAX  IpAddress
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The IP Address of the SMPT server. Note: This must be in dotted decimal form"
                  ::=  {  hhmsSensorArrayEntry 33  }

               hhmsSensorArrayMailGateway OBJECT-TYPE
                  SYNTAX  IpAddress
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "If the smpt server is on another network, enter the IP address of the router"
                  ::=  {  hhmsSensorArrayEntry 34  }

               hhmsSensorArrayMailUseGateway OBJECT-TYPE
                  SYNTAX  INTEGER {
      	         on(1),
                  off(2)
                  }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "If the mail uses the default gateway"
                  ::=  {  hhmsSensorArrayEntry 35  }

               hhmsSensorArrayMailResendInterval OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "How often to resend mail or Traps. Enter the number of seconds from 10 to 65535. Mail for WARNING and ERROR are resent at this interval. Mail for Normal status are sent once"
                  ::=  {  hhmsSensorArrayEntry 36  }

               hhmsSensorArrayMailMaxResend OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The maximum number of times to resend mail. If set to 0 only send once. The maximum value is 25"
                  ::=  {  hhmsSensorArrayEntry 37  }

               hhmsSensorArrayMailDestinationMac OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "If the mail destination MAC address, either the smpt server or the gateway"
                  ::=  {  hhmsSensorArrayEntry 38  }

               hhmsSensorArrayMailLastStatus OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The status of the most recent attempt to send an email"
                  ::=  {  hhmsSensorArrayEntry 39  }


               hhmsSensorArrayPowerControlTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArrayPowerControlEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the Power Control features in the sensorArray."
                  ::=  {  hhmsSensorArrayEntry 40   }

               hhmsSensorArrayPowerControlEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArrayPowerControlEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArrayPowerControlEntry Table"
                  INDEX         { hhmsSensorArrayPowerControlIndex }
                  ::=  { hhmsSensorArrayPowerControlTable 1 }

                  HhmsSensorArrayPowerControlEntry ::= SEQUENCE {
                     hhmsSensorArrayPowerModuleDescription
                        DisplayString,
                     hhmsSensorArrayPowerModuleStatus
                        INTEGER,
                     hhmsSensorArrayPowerModuleOnline
                        INTEGER,
                     hhmsSensorArrayPowerModuleGoOnline
                        INTEGER,
                     hhmsSensorArrayPowerOutletDescription
                        DisplayString,
                     hhmsSensorArrayPowerOutletStatus
                        INTEGER,
                     hhmsSensorArrayPowerOutletSet
                        INTEGER,
                     hhmsSensorArrayPowerControlIndex
                        INTEGER
                  }
                  hhmsSensorArrayPowerModuleDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this Power Module"
                     ::=  {  hhmsSensorArrayPowerControlEntry 1  }

                  hhmsSensorArrayPowerModuleStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
                     noStatus(1),
                     normal(2),
                     sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Sensor"
                     ::=  {  hhmsSensorArrayPowerControlEntry 2  }
      
                  hhmsSensorArrayPowerModuleOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
			            online(1),
			            offline(2)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "If this Sensor is currently online"
                        ::=  {  hhmsSensorArrayPowerControlEntry 3  }
   
                  hhmsSensorArrayPowerModuleGoOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         goOnline(1),
			            goOffline(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To put online enter a 1, to take offline enter a 2"
                     ::=  {  hhmsSensorArrayPowerControlEntry 4  }

                  hhmsSensorArrayPowerOutletDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this Power Port"
                     ::=  {  hhmsSensorArrayPowerControlEntry 5  }

                  hhmsSensorArrayPowerOutletStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
                     noStatus(1),
                     on(2),
                     off(3),
                     sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Sensor"
                     ::=  {  hhmsSensorArrayPowerControlEntry 6  }
      
                  hhmsSensorArrayPowerOutletSet OBJECT-TYPE
                     SYNTAX  INTEGER {
                     noStatus(1),
                     on(2),
                     off(3),
                     reboot(4),
                     sensorError(7)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Sensor"
                     ::=  {  hhmsSensorArrayPowerControlEntry 7  }

                  hhmsSensorArrayPowerControlIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..1)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the Power Control table"
                     ::=  {  hhmsSensorArrayPowerControlEntry 8   }


               hhmsSensorArrayPowerMonitorTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArrayPowerMonitorEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the Power Monitor features in the sensorArray."
                  ::=  {  hhmsSensorArrayEntry 41   }

               hhmsSensorArrayPowerMonitorEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArrayPowerMonitorEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArrayPowerMonitorEntry Table"
                  INDEX         { hhmsSensorArrayPowerMonitorIndex }
                  ::=  { hhmsSensorArrayPowerMonitorTable 1 }

                  HhmsSensorArrayPowerMonitorEntry ::= SEQUENCE {
                     hhmsSensorArrayPowerMonitorDescription
                        DisplayString,
                     hhmsSensorArrayPowerMonitorCurrent
                        INTEGER,
                     hhmsSensorArrayPowerMonitorVoltage
                        INTEGER,
                     hhmsSensorArrayPowerMonitorPower
                        DisplayString,
                     hhmsSensorArrayPowerMonitorStatus
                        INTEGER,
                     hhmsSensorArrayPowerMonitorOnline
                        INTEGER,
                     hhmsSensorArrayPowerMonitorGoOnline
                        INTEGER,
                     hhmsSensorArrayPowerMonitorHighWarning
                        INTEGER,
                     hhmsSensorArrayPowerMonitorHighCritical
                        INTEGER,
                     hhmsSensorArrayPowerMonitorLowWarning
                        INTEGER,
                     hhmsSensorArrayPowerMonitorLowCritical
                        INTEGER,
                     hhmsSensorArrayPowerMonitorRearm
                        INTEGER,
                     hhmsSensorArrayPowerMonitorIndex
                        INTEGER
                  }
                  hhmsSensorArrayPowerMonitorDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this Power Monitor"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 1  }

                  hhmsSensorArrayPowerMonitorCurrent OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The current in this sensor"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 2   }

                  hhmsSensorArrayPowerMonitorVoltage OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The voltage in this sensor"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 3   }

                  hhmsSensorArrayPowerMonitorPower OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The total energy measured so far by this sensor"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 4   }

                  hhmsSensorArrayPowerMonitorStatus OBJECT-TYPE
                     SYNTAX  INTEGER {
                     noStatus(1),
			            normal(2),
			            highWarning(3),
			            highCritical(4),
                     lowWarning(5),
                     lowCritical(6),
                     sensorError(7)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The current status of this Sensor"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 5  }
      
                  hhmsSensorArrayPowerMonitorOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
			            online(1),
			            offline(2)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "If this Sensor is currently online"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 6  }
   
                  hhmsSensorArrayPowerMonitorGoOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
                     goOnline(1),
			            goOffline(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To put online enter a 1, to take offline enter a 2"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 7  }

                  hhmsSensorArrayPowerMonitorHighWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How many watts of power this sensor detects before the sensor status is set to warning"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 8   }
      
                  hhmsSensorArrayPowerMonitorHighCritical OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How many watts of power this sensor detects before the sensor status is set to critical"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 9   }
   
                  hhmsSensorArrayPowerMonitorLowWarning OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How many watts of power this sensor detects before the sensor status is set to warning"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 10   }
   
                  hhmsSensorArrayPowerMonitorLowCritical OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How many watts of power this sensor detects before the sensor status is set to critical"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 11   }
      
                  hhmsSensorArrayPowerMonitorRearm OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How many watts of power this sensor detects to rearm the status. For example if status goes from normal to warning, the temp must go down hhmsTempRearm degrees below warning before the status goes to normal"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 12   }
   
                  hhmsSensorArrayPowerMonitorIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..4)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the Power table"
                     ::=  {  hhmsSensorArrayPowerMonitorEntry 13   }

               hhmsSensorArrayHighDriveTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArrayHighDriveEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the High Current Drivers in the sensorArray."
                  ::=  {  hhmsSensorArrayEntry 42   }

               hhmsSensorArrayHighDriveEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArrayHighDriveEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArrayHighDriveEntry Table"
                  INDEX         { hhmsSensorArrayHighDriveIndex }
                  ::=  { hhmsSensorArrayHighDriveTable 1 }

                  HhmsSensorArrayHighDriveEntry ::= SEQUENCE {
                     hhmsSensorArrayHighDriveDescription
                        DisplayString,
                     hhmsSensorArrayHighDriveOutputLevel
                        INTEGER,
                     hhmsSensorArrayHighDriveIndex
                        INTEGER
                  }

                  hhmsSensorArrayHighDriveDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this Power Monitor"
                     ::=  {  hhmsSensorArrayHighDriveEntry 1 }

                  hhmsSensorArrayHighDriveOutputLevel OBJECT-TYPE
                     SYNTAX  INTEGER {
		   	         closed(0),
			            open(1)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The Driver can be on or off. If closed the Open Collector will sink current. If open the Open Collector will tri state"
                     ::=  {  hhmsSensorArrayHighDriveEntry 2 }
   
                  hhmsSensorArrayHighDriveIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..3)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the HighDrive table"
                     ::=  {  hhmsSensorArrayHighDriveEntry 3 }

               hhmsSensorArrayCameraTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF HhmsSensorArrayCameraEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This table contains the Camera features in the sensorArray."
                  ::=  {  hhmsSensorArrayEntry 43   }

               hhmsSensorArrayCameraEntry OBJECT-TYPE
                  SYNTAX  HhmsSensorArrayCameraEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                  "This is an entry in the hhmsSensorArrayCameraEntry Table"
                  INDEX         { hhmsSensorArrayCameraIndex }
                  ::=  { hhmsSensorArrayCameraTable 1 }

                  HhmsSensorArrayCameraEntry ::= SEQUENCE {
                     hhmsSensorArrayCameraDescription
                        DisplayString,
                     hhmsSensorArrayCameraOnline
                        INTEGER,
                     hhmsSensorArrayCameraGoOnline
                        INTEGER,
                     hhmsSensorArrayCameraUrlMain
                        DisplayString,
                     hhmsSensorArrayCameraUrlExtension
                        DisplayString,
                     hhmsSensorArrayCameraRefreshRate
                        INTEGER,
                     hhmsSensorArrayCameraIndex
                        INTEGER
                  }

                  hhmsSensorArrayCameraDescription OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "A Description of this Camera"
                     ::=  {  hhmsSensorArrayCameraEntry 1  }

                  hhmsSensorArrayCameraOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
			            online(1),
			            offline(2)
                     }
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "If this Sensor is currently online"
                     ::=  {  hhmsSensorArrayCameraEntry 2  }
   
                  hhmsSensorArrayCameraGoOnline OBJECT-TYPE
                     SYNTAX  INTEGER {
                     goOnline(1),
			            goOffline(2)
                     }
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "To put online enter a 1, to take offline enter a 2"
                     ::=  {  hhmsSensorArrayCameraEntry 3  }

                  hhmsSensorArrayCameraUrlMain OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The URL of the Camera, for example http://10.1.1.7"
                     ::=  {  hhmsSensorArrayCameraEntry 4  }

                  hhmsSensorArrayCameraUrlExtension OBJECT-TYPE
                     SYNTAX  DisplayString
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "The cgi extension for the Picture from this Camera for example /webcam/server.jpg"
                     ::=  {  hhmsSensorArrayCameraEntry 5  }

                  hhmsSensorArrayCameraRefreshRate OBJECT-TYPE
                     SYNTAX  INTEGER
                     ACCESS  read-write
                     STATUS  mandatory
                     DESCRIPTION
                     "How often to refresh the image on the browser in seconds from 5 to 254"
                     ::=  {  hhmsSensorArrayCameraEntry 6  }

                  hhmsSensorArrayCameraIndex OBJECT-TYPE
                     SYNTAX  INTEGER (0..3)
                     ACCESS  read-only
                     STATUS  mandatory
                     DESCRIPTION
                     "The index into the Camera table"
                     ::=  {  hhmsSensorArrayCameraEntry 7  }

               hhmsSensorArrayTrapMailPollInterval OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "How often the sensor thresholds are tested before sending traps or mail. This can vary from 3 to 15 seconds"
                  ::=  {  hhmsSensorArrayEntry 50  }

               hhmsSensorArraySendTestMail OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "Send out an email test message"
                  ::=  {  hhmsSensorArrayEntry 51  }

               hhmsSensorArrayLastSystemError OBJECT-TYPE
                  SYNTAX  DisplayString
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "A text string containing the description of the last system error"
                  ::=  {  hhmsSensorArrayEntry 52  }

               hhmsSensorArrayDataCollectionPeriod OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The number of minutes between collections of the data logger. This can vary from 1 to 60 minutes"
                  ::=  {  hhmsSensorArrayEntry 53  }

               hhmsSensorArrayMailTimeout OBJECT-TYPE
                  SYNTAX  INTEGER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The number of seconds to wait for a timeout while sending email This can vary from 10 to 60 seconds"
                  ::=  {  hhmsSensorArrayEntry 54  }



      hhmsAgentConfig          OBJECT IDENTIFIER  ::=  {  hhmsagent 5   }

         hhmsAgentVersion OBJECT-TYPE
            SYNTAX  DisplayString
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
            "The hhms agent release version number"
            ::=  {  hhmsAgentConfig 1   }

         hhmsCompressedSummaryTable OBJECT-TYPE
            SYNTAX  SEQUENCE OF HhmsCompressedSummaryEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
            "This table contains a way to get summary info to the browser using minimum communication. One get contains a PDU info from multiple sensorArrays"
            ::=  {  hhmsAgentConfig 7   }

            hhmsCompressedSummaryEntry OBJECT-TYPE
               SYNTAX  HhmsCompressedSummaryEntry
               ACCESS  not-accessible
               STATUS  mandatory
               DESCRIPTION
               "This is an entry in the hhmsCompressedSummary Table"
               INDEX         { hhmsCompressedSummaryIndex }
               ::=  { hhmsCompressedSummaryTable 1 }

            HhmsCompressedSummaryEntry ::= SEQUENCE {
               hhmsCompressedSummaryGet
                  DisplayString,
               hhmsCompressedSummaryIndex
                  INTEGER
               }

            hhmsCompressedSummaryGet OBJECT-TYPE
               SYNTAX  DisplayString
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
               "Get multiple compressed summary PDU"
               ::=  {  hhmsCompressedSummaryEntry 1   }

            hhmsCompressedSummaryIndex OBJECT-TYPE
               SYNTAX  INTEGER (0..1)
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
               "The index into the compressed summary table"
               ::=  {  hhmsCompressedSummaryEntry 2   }

--
-- Varbinds used in TRAP Definitions
--

      hhmsAgentTraps      OBJECT IDENTIFIER  ::=  {  hhmsagent 7   }

      hhmsSensorStatus OBJECT-TYPE
            SYNTAX  INTEGER {
               noStatus(1),
               normal(2),
               highWarning(3),
               highCritical(4),
               lowWarning(5),
               lowCritical(6),
               sensorError(7)
				}
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
         "The current integer status of the sensor causing this trap to be sent"
         ::=  {  hhmsAgentTraps 1  }
      
      hhmsSensorValue OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
         "The current integer value of the sensor causing this trap to be sent"
         ::=  {  hhmsAgentTraps 2  }
      
      hhmsSensorLevelExceeded OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
         "The integer level that was exceeded causing this trap to be sent"
         ::=  {  hhmsAgentTraps 3  }
      

      hhmsSensorIndex OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
         "The integer index of the sensor causing this trap to be sent"
         ::=  {  hhmsAgentTraps 4  }
      

      hhmsSensorName OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
         "The name of the sensor causing this trap to be sent"
         ::=  {  hhmsAgentTraps 5  }
      
      hhmsSensorDescription OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
         "The description of the sensor causing this trap to be sent"
         ::=  {  hhmsAgentTraps 6  }
      

-- TRAP Definitions


	hhmsUnknownStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		DESCRIPTION
			"hhmsagent status went to Unknown"
		::= 0

	hhmsNormalStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		DESCRIPTION
			"hhmsagent status is Normal"
		::= 1

	hhmsWarningStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		DESCRIPTION
			"hhmsagent status went to Warning"
		::= 2

	hhmsCriticalStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		DESCRIPTION
			"hhmsagent status went to Critical"
		::= 3

	hhmsDownStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		DESCRIPTION
			"hhmsagent status went to Disabled"
		::= 4

	hhmsTemperatureStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		VARIABLES
			{ hhmsSensorStatus, hhmsSensorValue, hhmsSensorLevelExceeded, 
         hhmsSensorIndex, hhmsSensorName, hhmsSensorDescription }
		DESCRIPTION
			"Temperature sensor trap"
		::= 10

	hhmsHumidityStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		VARIABLES
			{ hhmsSensorStatus, hhmsSensorValue, hhmsSensorLevelExceeded, 
         hhmsSensorIndex, hhmsSensorName, hhmsSensorDescription }
		DESCRIPTION
			"Humidity sensor trap"
		::= 20

	hhmsSwitchStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		VARIABLES
			{ hhmsSensorStatus, hhmsSensorValue, hhmsSensorLevelExceeded, 
         hhmsSensorIndex, hhmsSensorName, hhmsSensorDescription }
		DESCRIPTION
			"Switch sensor trap"
		::= 30

	hhmsPowerMonitorStatus TRAP-TYPE
		ENTERPRISE hhmsagent
		VARIABLES
			{ hhmsSensorStatus, hhmsSensorValue, hhmsSensorLevelExceeded, 
         hhmsSensorIndex, hhmsSensorName, hhmsSensorDescription }
		DESCRIPTION
			"Power Monitor sensor trap"
		::= 40

END